How Far Above Roof For Wood Stove Poipe

The termination cap is installed above this point.
How far above roof for wood stove poipe. The stovepipe connects with the insulated chimney at a special support box located just below the ceiling level. If no wall protection is used the common radiant type stove or heater must be spaced out at least 36 inches from the wall. For gas vents or a type l vent this distance above the roof surface must be at least 2 ft 0 61m. All chimneys must extend 3 feet above the roof surface and 2 feet higher than any part of the building within 10 feet.
Most wood stove and factory built fireplace manufacturers and local building codes will require that the chimney must extend at least 2 feet above any portion of any structure within 10 feet measured horizontally and must extend at least 3 feet above the highest point of its roof penetration. If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet. This specification makes sure steep roof slopes are cleared. A 1 inch or wider air.
In other words the highest point within a 10 foot circle of the pipe. Determine the number of chimney pipe lengths required. Minimum three feet above the high side of the roof at least two feet taller than anything within ten feet the portion of the rule stating the pipe needs to be 2 feet above anything within 10 feet is where most people get confused. The insulated chimney pipe is stacked until it reaches the required height.
This distance may be reduced considerably if asbestos millboard and or 28 gage sheet metal is used for wall protection.