Honeywell Universal Combination Fan And Limit Control

Universal combination fan and limit controllers application these combination warm air fan and limit controllers are suitable for various types of forced air heating systems.
Honeywell universal combination fan and limit control. Honeywell l4064b2236 combination fan and limit furnace control. This limit switch has a push pull button on it that does the same. Honeywell 1985 douglas drive north golden valley mn 55422 3992. Honeywell l4064b2236 combination fan and limit furnace control 4 5 out of 5 stars 165.
For control of high limit and fan motor in all types of forced air heating systems. 1 do not exceed the following electrical ratings amperes. Emerson 5d51 35 universal replacement fan and limit control with 5 element. Goodman oem furnace 11 replacement combination fan limit switch.
Honeywell l4064b2236 combination fan and limit furnace control 89 95 only 11 left in stock order soon. Get it as soon as wed. One which opens the limit circuit if the plenum temperature exceeds the preset safety limit. L4064r 250 ºf 121 ºc above limit setting.
L4064b r 190 ºf 88 ºc. Electrical ranges to. Here are the functions and and normal settings for the warm air heating furnace control switch such as the honeywell tradeline l4046 and 4046b combination fan and limit control. Honeywell l4069a 1060 fan limit control adjustable range 180 250 degrees f 7in insertion open circuit stop set at 200 degrees f 37 48 37.
Page 2 l4064b l4064r universal combination fan and limit controllers surface mounting fig. L4029e reset limit control opens a line or low voltage circuit if the air temperature reaches a critical level. 4 5 out of 5 stars 165. During the installation my previous fan limit switch had a low connection for the fan on switch.
L4064b hole in plenum should be just large enough table 1. The controllers have 2 switches. The l4064bõ s bimetal sensing element turns fan on and of f according to plenum temperature. L4064b l4064r universal combination fan and limit controllers home and building technologies in the u s.
Universal combination fan and limit controllers applica tion the l4064b controls the on and of f operation of the heating unitõ s fan motor and provides high limit control of the main burner. L4029e acts as a fire thermostat in the ducts of ac ventilating systems. Maximum switch temperature is. The other switch turns.
4 8 out of 5 stars 5. If the air temperature indicates a fire the fan is shut down. White rodgers universal hot surface ignition module 4 7 out of 5 stars 158.