Are 2 65 and 2 7 respectively.
High strength concrete mix design pdf. This design guide serves to extend the use of concrete beyond grade 60 in the design of concrete structures using cp65. The dry rodded bulk density of c a. Design a concrete mix for construction of an elevated water tank. F high strength concrete mix design g mix design based on flexural strength h road note no.
For new construction or repairs where concrete thickness exceeds 2 inches you ll want to count on a preblended mixture that can. Now what is mix design. For a given type of cement and aggregates used the reference number corresponding to the design strength at a particular age is interpolated from figure 1 to 4. Hence it is intended for use by engineers familiar with the design of concrete structures using particularly cp65 but who have little or no experience of high strength concrete hsc.
Although the american concrete institute aci doesn t use the term preferring mix proportioning. The use of this quality mixture ensuring your finished project will last you for years to come. 4 grading curve method i aci committee 211 method j doe method k mix design for pumpable concrete l indian standard recommended method is 10262 82 out of the above methods some of them are not very widely used these days because. Mix design of high strength concrete procedure.
Water water cement ratio. Understand concrete mix design submittal and approval process for ncdot know how to correctly complete ncdot mix design forms. Iii high early strength iv low heat of hydration v high sulfate resistance ncdot table 1024 1. Sakrete high strength concrete mix is a preblended mixture of sand coarse aggregate and cementitious materials.
The specific gravity of fa and c a. The type of concrete generally with compressive strength of 6000psi 40mpa or greater is called as hsc. The initial stage began in the 1950s when hsc was studied and applied to prestressed concrete structures. Cement c concrete.
Is 1600 kg m3 and fineness modulus of fa is 2 80. The specified design strength of concrete is 30 mpa at 28 days measured on standard cylinders. But keeping in view the modern knowledge of concrete especially in case of high strength concrete we should improve the term. Table 1 typical compressive strength1 compressive strength astm c39 age typical values 7 days 2500 psi 17 2 mpa 28 days 4000 psi 27 6 mpa slump range 2 3 51 76 mm 1.
The mean design strength is obtained by applying suitable control factors to the specified minimum strength. Download full text pdf read full text.